@article{oai:muroran-it.repo.nii.ac.jp:00010112, author = {原田, 怜 and HARADA, Rei and 星野, 賢治 and HOSHINO, Kenji and 秋岡, 民康 and AKIOKA, Tamiyasu and 小室, 雅人 and KOMURO, Masato and 栗橋, 祐介 and KURIHASHI, Yusuke and 梅沢, 広幸 and UMEZAWA, Hiroyuki}, journal = {構造工学論文集. A, Journal of structural engineering. A}, month = {}, note = {application/pdf, Protection Nets have been clarified as one of the countermeasures to protect facilities of Nuclear Power Plants against Tornado Missile. This research shows the performance of the Net Protection System, which has no anisotropy and high energy absorbing capacity, by conducting the free-fall test with Tornado Missile according to the “Assessment guide for tornado effect on nuclear power plants”. As a result of the test, the capacity and safety ratio of this system against series of impacts were confirmed, when the Tornado Missile hits the center and the corner point in the net, even when it hits the same point multiple times. Furthermore, this research concludes the method to calculate the amount of absorbing energy of Ring nets after clearing up the dynamic response of the system.}, pages = {1072--1083}, title = {リングネットを用いた防護ネットシステムに対する竜巻飛来物の自由落下試験}, volume = {62A}, year = {2016}, yomi = {ハラダ, レイ and ホシノ, ケンジ and アキオカ, タミヤス and コムロ, マサト and クリハシ, ユウスケ and ウメザワ, ヒロユキ} }