| アイテムタイプ |
学術雑誌論文 / Journal Article.(1) |
| 公開日 |
2022-03-24 |
| 書誌情報 |
en : MATERIALS
巻 14,
号 15,
p. 4216,
発行日 2021
|
| タイトル |
|
|
タイトル |
Microstructure and Properties of SUS304 Stainless Steel Joints Brazed with Electrodeposited Ni-Cr-P Alloy Coatings |
|
言語 |
en |
| 言語 |
|
|
言語 |
eng |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
electrodeposited Ni-Cr-P coating |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
brazing filler metal |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
microstructure |
| キーワード |
|
|
言語 |
en |
|
主題Scheme |
Other |
|
主題 |
shear strength |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
| アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
| 著者 |
Liu, Shubin
荘司, 郁夫
Kobayashi, Tatsuya
Osanai, Katsuharu
安藤, 哲也
Hirohashi, Junichiro
Wake, Tsunehito
Inoue, Katsufumi
Yamamoto, Hiroki
|
| 室蘭工業大学研究者データベースへのリンク |
|
|
表示名 |
安藤 哲也(ANDO Tetsuya) |
|
URL |
http://rdsoran.muroran-it.ac.jp/html/100000115_ja.html |
| 抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
In this study, an amorphous Ni-13.4Cr-11.6P (mass%) alloy coating with a thickness of 30 mu m was deposited on the surface of SUS304 stainless steel as a brazing filler metal to conduct brazing. The differential thermal analysis measurements indicate that the electrodeposited Ni-13.4Cr-11.6P alloy has a melting point of approximately 892 degrees C, which is almost consistent with that of the commercial BNi-7 filler metal. The microstructure, shear strength, and fracture mode of the brazed joint were investigated using an electron probe X-ray microanalyzer, a scanning electron microscope, an optical microscope, and a universal testing machine. The results showed that the brazed filler metal is filled between the SUS304 stainless steel plates without any flaws in the brazed seam. The P-containing phases, i.e., the Cr-P rich phase and the (Ni,Fe)(3)P phase, were formed in the brazed seam. The shear strength of the brazed joint obtained in this study is 59.0 MPa. The fracture occurs in the brazed filler zone, where the brittle P-containing phases are present. Galvanic current measurement results showed that the brazed Ni-13.4Cr-11.6P alloy coating has a better corrosion resistance than that of the brazed Ni-11P alloy coating, which can be attributed to the formation of a large amount of Ni-Fe solid solution and Cr-P rich phase in the top layer of the brazed Ni-13.4Cr-11.6P alloy coating. |
|
言語 |
en |
| 出版者 |
|
|
出版者 |
MDPI |
|
言語 |
en |
| 出版者版へのリンク |
|
|
表示名 |
10.3390/ma14154216 |
|
URL |
https://doi.org/10.3390/ma14154216 |
| DOI |
|
|
関連タイプ |
isIdenticalTo |
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
10.3390/ma14154216 |
| 日本十進分類法 |
|
|
主題Scheme |
NDC |
|
主題 |
564 |
| 権利 |
|
|
権利情報 |
https://creativecommons.org/licenses/by/4.0/ |
|
言語 |
en |
| 著者版フラグ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| フォーマット |
|
|
内容記述タイプ |
Other |
|
内容記述 |
application/pdf |