@article{oai:muroran-it.repo.nii.ac.jp:00010570, author = {小坂, 英之 and KOSAKA, Hideyuki and 溝口, 光男 and MIZOGUCHI, Mitsuo}, issue = {700}, journal = {日本建築学会構造系論文集}, month = {}, note = {application/pdf, This paper discusses a strength evaluation method of precast multi-story shear wall system which allows slip failure of the vertical joint between wall panels and boundary columns. Shear force of the vertical joint is transmitted by cotters and the joint reinforcements of beam position. Ultimate strength of the wall system is evaluated by adding strength of a wall panel by the calculation method shown in our previous paper and shear forces of the columns. The results of this method were compared with loading tests of the precast wall systems. The calculated values were in good agreement with the experiments.}, pages = {819--827}, title = {鉛直接合部の滑り破壊を許容したプレキャスト連層耐震壁の強度評価 : 鉄筋コンクリート連層壁板の強度算定法(その2)}, volume = {79}, year = {2014}, yomi = {コサカ, ヒデユキ and ミゾグチ, ミツオ} }