{"created":"2023-06-19T10:26:54.167632+00:00","id":5643,"links":{},"metadata":{"_buckets":{"deposit":"67b6132f-1207-4617-bd36-c5b66940c93a"},"_deposit":{"created_by":18,"id":"5643","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"5643"},"status":"published"},"_oai":{"id":"oai:muroran-it.repo.nii.ac.jp:00005643","sets":["46"]},"author_link":["37063","8657","25900","26924"],"item_79_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1996-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"486","bibliographicPageEnd":"34","bibliographicPageStart":"27","bibliographic_titles":[{"bibliographic_title":"日本建築学会計画系論文集","bibliographic_titleLang":"ja"}]}]},"item_79_description_23":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_79_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Temperature variations of full-size ceiling insulation model and roof insuration model are measured and observed to prevent melting and freezing of snow on the roof during winter. As a result, roof insulation model with ventilated air space is quite effective to prevent the problem caused by snowmelting on the roof since the temperature inside the ventilated air space follow the outside temperature well. On the other hand, ceiling insulation model leaves much room for improvement on ventilaion method in attic space because of the bad followrity of temperature inside the attic space.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_79_publisher_11":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会","subitem_publisher_language":"ja"}]},"item_79_relation_15":{"attribute_name":"論文ID(NAID)","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"110004654392","subitem_relation_type_select":"NAID"}}]},"item_79_rights_19":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright 1996 日本建築学会 ダウンロードを含むこの著作物の利用は、著作権法の私的使用及び引用の範囲に限り認められます。その範囲外の利用については、日本建築学会 の承諾が必要です。本文データは 日本建築学会 の許諾に基づきCiNiiから複製したものです。","subitem_rights_language":"ja"}]},"item_79_source_id_12":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13404210","subitem_source_identifier_type":"PISSN"}]},"item_79_source_id_14":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10438548","subitem_source_identifier_type":"NCID"}]},"item_79_subject_9":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"511","subitem_subject_scheme":"NDC"}]},"item_79_version_type_21":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"鈴木, 大隆","creatorNameLang":"ja"},{"creatorName":"SUZUKI, Hirotaka","creatorNameLang":"en"},{"creatorName":"スズキ, ヒロタカ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"廣田, 誠一","creatorNameLang":"ja"},{"creatorName":"HIROTA, Tomohito","creatorNameLang":"en"},{"creatorName":"ヒロタ, トモヒト","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"本間, 義規","creatorNameLang":"ja"},{"creatorName":"HONMA, Yoshinori","creatorNameLang":"en"},{"creatorName":"ホンマ, ヨシノリ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"鎌田, 紀彦","creatorNameLang":"ja"},{"creatorName":"KAMATA, Norihiko","creatorNameLang":"en"},{"creatorName":"カマタ, ノリヒコ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-15"}],"displaytype":"detail","filename":"apeet486_27_1996.pdf","filesize":[{"value":"957.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"apeet486_27_1996.pdf","objectType":"fulltext","url":"https://muroran-it.repo.nii.ac.jp/record/5643/files/apeet486_27_1996.pdf"},"version_id":"0ed8e2f8-0f30-4614-9cd2-a11be76d3f92"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"天井断熱","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"小屋裏空間","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"屋根断熱","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"通気層","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"温度","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"ceiling-insulation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"atttic space","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"roof-insulation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"air space","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"temperature","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"傾斜屋根における天井断熱・屋根断熱モデルの冬期温度特性について : 積雪寒冷地の断熱気密化住宅における小屋裏換気手法に関する研究(その1)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"傾斜屋根における天井断熱・屋根断熱モデルの冬期温度特性について : 積雪寒冷地の断熱気密化住宅における小屋裏換気手法に関する研究(その1)","subitem_title_language":"ja"},{"subitem_title":"EXPERIMENTAL STUDY ON TEMPERATURE VARIATIONS IN THE ATTIC SPACE OF CEILING INSULATION MODEL AND IN THE VENTILATED AIR SPACE OF ROOF INSULATION MODEL IN INCLINED ROOF DURING WINTER : Ventilation method in attic space of insulated and airtight house to prevent snowmelting in cold region Part 1","subitem_title_language":"en"}]},"item_type_id":"79","owner":"18","path":["46"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2013-03-04"},"publish_date":"2013-03-04","publish_status":"0","recid":"5643","relation_version_is_last":true,"title":["傾斜屋根における天井断熱・屋根断熱モデルの冬期温度特性について : 積雪寒冷地の断熱気密化住宅における小屋裏換気手法に関する研究(その1)"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-12-15T06:18:27.344039+00:00"}