{"created":"2023-06-19T10:26:56.225940+00:00","id":5692,"links":{},"metadata":{"_buckets":{"deposit":"810cf67b-91a7-4aa0-9852-782597aaeb0f"},"_deposit":{"created_by":18,"id":"5692","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"5692"},"status":"published"},"_oai":{"id":"oai:muroran-it.repo.nii.ac.jp:00005692","sets":["46"]},"author_link":["25187","25900","37063","26924","8657"],"control_number":"5692","item_79_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1998-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"504","bibliographicPageEnd":"31","bibliographicPageStart":"25","bibliographic_titles":[{"bibliographic_title":"日本建築学会計画系論文集","bibliographic_titleLang":"ja"}]}]},"item_79_description_23":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_79_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Ventilation method in ventilated 30° pitched-roofs are examined to prevent icicle and ice dams forming on the inclined roof of insulated and airtight house. Simulation code that can be approximated measurement temperatures of the experimental house were developed, and was analyzed temperature of ventilating roofs with different insulation thickness and different ventilation method, under the several house location. From the simulation results, the effectiveness of the ridge opening is obvious, and the high insulation thickness can reduce ventilation rate. It also made clear that the ventilation rate of ventilating attic space is rather small for preventing icing at eaves, it especially means normalized opening at eaves or ridge on top should be made bigger anyhow from the architectural point of view.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_79_publisher_11":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会","subitem_publisher_language":"ja"}]},"item_79_relation_15":{"attribute_name":"論文ID(NAID)","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"110004654961","subitem_relation_type_select":"NAID"}}]},"item_79_rights_19":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright 1998 日本建築学会 ダウンロードを含むこの著作物の利用は、著作権法の私的使用及び引用の範囲に限り認められます。その範囲外の利用については、日本建築学会 の承諾が必要です。本文データは 日本建築学会 の許諾に基づきCiNiiから複製したものです。","subitem_rights_language":"ja"}]},"item_79_source_id_12":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13404210","subitem_source_identifier_type":"PISSN"}]},"item_79_source_id_14":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10438548","subitem_source_identifier_type":"NCID"}]},"item_79_subject_9":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"511","subitem_subject_scheme":"NDC"}]},"item_79_version_type_21":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"鈴木, 大隆","creatorNameLang":"ja"},{"creatorName":"SUZUKI, Hirotaka","creatorNameLang":"en"},{"creatorName":"スズキ, ヒロタカ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"本間, 義規","creatorNameLang":"ja"},{"creatorName":"HONMA, Yoshinori","creatorNameLang":"en"},{"creatorName":"ホンマ, ヨシノリ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"廣田, 誠一","creatorNameLang":"ja"},{"creatorName":"HIROTA, Tomohito","creatorNameLang":"en"},{"creatorName":"ヒロタ, トモヒト","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"鎌田, 紀彦","creatorNameLang":"ja"},{"creatorName":"KAMATA, Norihiko","creatorNameLang":"en"},{"creatorName":"カマタ, ノリヒコ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"坂本, 弘志","creatorNameLang":"ja"},{"creatorName":"SAKAMOTO, Hiroshi","creatorNameLang":"en"},{"creatorName":"サカモト, ヒロシ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-15"}],"displaytype":"detail","filename":"apeet504_25_1998.pdf","filesize":[{"value":"1.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"apeet504_25_1998.pdf","objectType":"fulltext","url":"https://muroran-it.repo.nii.ac.jp/record/5692/files/apeet504_25_1998.pdf"},"version_id":"c458c979-c10e-419f-b15e-656494fc0182"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"断熱換気方式","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"積雪障害防止","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"小屋裏温度","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"通気層内温度","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"数値解析","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"Insulation and ventilation methods","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"prevention of problematic icing","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"temperature in the attic space","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"temperature in the ventilated roof air space","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"numerical simulation","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"30°勾配屋根住宅の立地条件や断熱・換気条件を考慮した小屋裏・通気層温度解析結果と考察 : 積雪寒冷地の断熱気密化住宅における小屋裏換気手法に関する研究(その2)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"30°勾配屋根住宅の立地条件や断熱・換気条件を考慮した小屋裏・通気層温度解析結果と考察 : 積雪寒冷地の断熱気密化住宅における小屋裏換気手法に関する研究(その2)","subitem_title_language":"ja"},{"subitem_title":"A NUMERICAL STUDY ON TEMPERATURE IN THE VENTILATED 30° PITCHED-ROOFS IN WINTER WITH DIFFERENT INSULATION AND VENTILATION METHODS, AND CONDITION OF THE HOUSE LOCATION : Study on ventilated roofs of insulated and airtight house to prevent problematic icing on the roof in cold region Part2","subitem_title_language":"en"}]},"item_type_id":"79","owner":"18","path":["46"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2013-03-04"},"publish_date":"2013-03-04","publish_status":"0","recid":"5692","relation_version_is_last":true,"title":["30°勾配屋根住宅の立地条件や断熱・換気条件を考慮した小屋裏・通気層温度解析結果と考察 : 積雪寒冷地の断熱気密化住宅における小屋裏換気手法に関する研究(その2)"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-12-15T06:19:22.071465+00:00"}