@article{oai:muroran-it.repo.nii.ac.jp:00005742, author = {鎌田, 紀彦 and KAMATA, Norihiko and 鈴木, 大隆 and SUZUKI, Hirotaka and 小笠原, 一隆 and OGASAWARA, Kazutaka and 北谷, 幸恵 and KITADANI, Yukie and 本間, 義規 and HONMA, Yoshinori}, issue = {516}, journal = {日本建築学会計画系論文集}, month = {Feb}, note = {application/pdf, The thermal insulation, heating, and ventilation systems of four typical existing detached houses were upgraded to meet current building standards, Air leakage was reduced to 2 cm^2 per 1 m^2 of floor area and the hygrothermal condition of the crawl space of the vertical edge insulation of the foundation walls was also improved. Thermal comfort in the living areas of the houses and their internal temperature distribution were brought up to Sapporo's new energy conservation code levels, The cost of each upgrading, excluding heating equipment, was found to be approximately 6 million yen per house.}, pages = {23--30}, title = {北海道の戸建住宅における断熱改修の応用的研究}, year = {1999}, yomi = {カマタ, ノリヒコ and スズキ, ヒロタカ and オガサワラ, カズタカ and キタダニ, ユキエ and ホンマ, ヨシノリ} }