{"created":"2023-06-19T10:27:09.266704+00:00","id":6006,"links":{},"metadata":{"_buckets":{"deposit":"76bfba86-2fab-404a-ae28-f3bcbcfa6c84"},"_deposit":{"created_by":18,"id":"6006","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"6006"},"status":"published"},"_oai":{"id":"oai:muroran-it.repo.nii.ac.jp:00006006","sets":["46"]},"author_link":["26923","26925","26926","26924","8657"],"item_79_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2001-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"14","bibliographicPageEnd":"180","bibliographicPageStart":"177","bibliographic_titles":[{"bibliographic_title":"日本建築学会技術報告集","bibliographic_titleLang":"ja"}]}]},"item_79_description_23":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_79_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper presents the development of warm air heating system using crawl-space as heating chamber for single family house. To establish proper system, required opening area for air convection on the floor and air convection wall, is discussed through simulation. Developed system is applied to the practical house and their performances are measured. The results indicate that this system creates comfortable indoor thermal environment in the heating season.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_79_publisher_11":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会","subitem_publisher_language":"ja"}]},"item_79_relation_15":{"attribute_name":"論文ID(NAID)","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"110003798785","subitem_relation_type_select":"NAID"}}]},"item_79_rights_19":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright 2001 日本建築学会 ダウンロードを含むこの著作物の利用は、著作権法の私的使用及び引用の範囲に限り認められます。その範囲外の利用については、日本建築学会 の承諾が必要です。本文データは 日本建築学会 の許諾に基づきCiNiiから複製したものです。","subitem_rights_language":"ja"}]},"item_79_source_id_12":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13419463","subitem_source_identifier_type":"PISSN"}]},"item_79_source_id_14":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10531441","subitem_source_identifier_type":"NCID"}]},"item_79_subject_9":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"511","subitem_subject_scheme":"NDC"}]},"item_79_version_type_21":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"福島, 明","creatorNameLang":"ja"},{"creatorName":"FUKUSHIMA, Akira","creatorNameLang":"en"},{"creatorName":"フクシマ, アキラ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"鎌田, 紀彦","creatorNameLang":"ja"},{"creatorName":"KAMATA, Norihiko","creatorNameLang":"en"},{"creatorName":"カマタ, ノリヒコ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"本間, 義規","creatorNameLang":"ja"},{"creatorName":"HONMA, Yoshinori","creatorNameLang":"en"},{"creatorName":"ホンマ, ヨシノリ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"絵内, 正道","creatorNameLang":"ja"},{"creatorName":"ENAI, Masamichi","creatorNameLang":"en"},{"creatorName":"エナイ, マサミチ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"西田, 和宏","creatorNameLang":"ja"},{"creatorName":"NISHIDA, Kazuhiro","creatorNameLang":"en"},{"creatorName":"ニシダ, カズヒロ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-15"}],"displaytype":"detail","filename":"jtd14_177_2001.pdf","filesize":[{"value":"503.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"jtd14_177_2001.pdf","objectType":"fulltext","url":"https://muroran-it.repo.nii.ac.jp/record/6006/files/jtd14_177_2001.pdf"},"version_id":"c8e8b90d-3cff-44cb-92ab-af880f74902f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"床下空間","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"温度環境","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"暖房システム","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"空気循環","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"Crawl space","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Thermal environment","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Heating system","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Air convection","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"床下空間を利用した空気循環型全室暖房システムの開発と適用","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"床下空間を利用した空気循環型全室暖房システムの開発と適用","subitem_title_language":"ja"},{"subitem_title":"DEVELOPMENT AND APLICATION OF WARM AIR HEATING SYSTEM USING CRAWL SPACE","subitem_title_language":"en"}]},"item_type_id":"79","owner":"18","path":["46"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2013-03-04"},"publish_date":"2013-03-04","publish_status":"0","recid":"6006","relation_version_is_last":true,"title":["床下空間を利用した空気循環型全室暖房システムの開発と適用"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-12-15T06:16:30.622898+00:00"}