{"created":"2023-06-19T10:27:25.140626+00:00","id":6381,"links":{},"metadata":{"_buckets":{"deposit":"0a90e947-e4b6-4340-b2f5-7b08bb637d89"},"_deposit":{"created_by":18,"id":"6381","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"6381"},"status":"published"},"_oai":{"id":"oai:muroran-it.repo.nii.ac.jp:00006381","sets":["216:407:281","46"]},"author_link":["8490","45401","45402","50839"],"item_79_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"591","bibliographicPageEnd":"75","bibliographicPageStart":"69","bibliographic_titles":[{"bibliographic_title":"日本建築学会構造系論文集","bibliographic_titleLang":"ja"}]}]},"item_79_description_23":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_79_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Installation model tests of screwed steel pipe pile, which has helical wing on the pile edge, were executed in uniformly graded high density sand in a calibration chamber. The experimental factors are the pile diameter D_0 (48.6, 76.3, 101.6mm) and the surcharge pressure σ_v (50, 100, 150kPa). The results show the residual stresses, which remain in the screwed pile after installation, amount to high ratio for the stresses during installation. We have discussed the penetration mechanism of the screwed pile based on the stress distribution in the cross section of the pile.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_79_publisher_11":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会","subitem_publisher_language":"ja"}]},"item_79_relation_15":{"attribute_name":"論文ID(NAID)","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"110004839695","subitem_relation_type_select":"NAID"}}]},"item_79_rights_19":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright 2005 日本建築学会 ダウンロードを含むこの著作物の利用は、著作権法の私的使用及び引用の範囲に限り認められます。その範囲外の利用については、日本建築学会の承諾が必要です。本文データは学協会の許諾に基づきCiNiiから複製したものです。","subitem_rights_language":"ja"}]},"item_79_source_id_12":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13404202","subitem_source_identifier_type":"PISSN"}]},"item_79_source_id_14":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10438559","subitem_source_identifier_type":"NCID"}]},"item_79_subject_9":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"511","subitem_subject_scheme":"NDC"}]},"item_79_version_type_21":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"大杉, 富美一","creatorNameLang":"ja"},{"creatorName":"OHSUGI, Fumikazu","creatorNameLang":"en"},{"creatorName":"オオスギ, フミカズ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"土屋, 勉","creatorNameLang":"ja"},{"creatorName":"TSUCHIYA, Tsutomu","creatorNameLang":"en"},{"creatorName":"ツチヤ, ツトム","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"島田, 正夫","creatorNameLang":"ja"},{"creatorName":"SHIMADA, Masao","creatorNameLang":"en"},{"creatorName":"シマダ, マサオ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"吉田, 勝之","creatorNameLang":"ja"},{"creatorName":"YOSHIDA, Katsuyuki","creatorNameLang":"en"},{"creatorName":"ヨシダ, カツユキ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-15"}],"displaytype":"detail","filename":"aijt591_69_2005.pdf","filesize":[{"value":"692.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"aijt591_69_2005.pdf","objectType":"fulltext","url":"https://muroran-it.repo.nii.ac.jp/record/6381/files/aijt591_69_2005.pdf"},"version_id":"8d83cf62-757d-4bcc-b2b1-6654d238bb21"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"回転貫入杭","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"施工実験","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"加圧土槽","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"残留応力","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"貫入メカニズム","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"screwed pile","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"installation test","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"calibration chamber","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"residual stress","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"penetration mechanism","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"大型加圧土槽を利用した回転貫入模型杭の貫入実験","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"大型加圧土槽を利用した回転貫入模型杭の貫入実験","subitem_title_language":"ja"},{"subitem_title":"PILE INSTALLATION TESTS OF SCREWED PILES IN A CALLIBRATION CHAMBER","subitem_title_language":"en"}]},"item_type_id":"79","owner":"18","path":["46","281"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-07-11"},"publish_date":"2012-07-11","publish_status":"0","recid":"6381","relation_version_is_last":true,"title":["大型加圧土槽を利用した回転貫入模型杭の貫入実験"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2023-11-13T00:59:43.232032+00:00"}