@inproceedings{oai:muroran-it.repo.nii.ac.jp:00006413, author = {SATO, Kazuhiko and 佐藤, 和彦 and 大西, 覚 and OHNISHI, Satoru and AMBARITA, Himsar and アムバリタ, ヒムサール and 小川, 光一 and OGAWA, Koichi and 黒谷, 博史 and KUROTANI, Hiroshi and 鈴木, 淳 and SUZUKI, Jun and 岸浪, 紘機 and KISHINAMI, Koki}, book = {環境工学総合シンポジウム講演論文集}, month = {Jul}, note = {application/pdf, Cross/counter flow types of heat exchanger seem likely to have superior characteristics in regard to design a large heat transfer surface area per unit volume by alternately laminating the elements. In this paper, a cross flow type of heat exchanger are examined by experiment, and inserted plate with/without slit holes setting in ducts are proposed to be up the exchanging heat performance from the view point of the enhancement of heat transfer coefficient and pressure loss decreasing, substituting the conventional heat transfer surface increasing technique. Experimental results for 4 cases (CFHE without inserted plate, and inserted plate with/without slit holes) are discussed as a relation of temperature effectiveness and number of heat transfer unit and exergy transfer, referred to the numerical results taking the effect of the inserted plate with/without slit holes on flow, heat transfer behaviors and pressure decreasing into consideration.}, pages = {531--534}, publisher = {日本機械学会}, title = {直交流型熱交換器に関する研究 : 伝熱ダクト内にスリット付挿入板を設置した場合}, volume = {15}, year = {2005}, yomi = {サトウ, カズヒコ and オオニシ, サトル and オガワ, コウイチ and スズキ, ジュン and キシナミ, コウキ} }