@article{oai:muroran-it.repo.nii.ac.jp:00006608, author = {青野, 義道 and AONO, Yoshimichi and 松下, 文明 and MATSUSHITA, Fumiaki and 柴田, 純夫 and SHIBATA, Sumio and 濱, 幸雄 and HAMA, Yukio}, issue = {607}, journal = {日本建築学会構造系論文集}, month = {Sep}, note = {application/pdf, Effect of drying and wetting cycles on frost resistance of concrete was evaluated by the ASTM C666 A and the GIF. Both methods showed that drying and wetting cycles deteriorated the frost resistance of non-AE high performance concrete. Though the micro cracks were observed, the effect on the frost damage was not proven. Change in microstructure of hardening cement paste by drying and wetting cycles was also studied by means of mercury intrusion porosimetry and NMR. Micro pores around 50-100nm in diameter increased. The NMR spectra identified to Q_0 and Q_1 decreased, while Q_2 increased, showing the condensation of silicate anion structure.}, pages = {15--22}, title = {乾湿繰り返しが及ぼすコンクリートの耐凍害性への影響とその劣化メカニズムに関する研究}, year = {2006}, yomi = {アオノ, ヨシミチ and マツシタ, フミアキ and シバタ, スミオ and ハマ, ユキオ} }