{"created":"2023-06-19T10:28:34.764411+00:00","id":8030,"links":{},"metadata":{"_buckets":{"deposit":"995a53b3-b85e-4ac6-b73e-1132be75518c"},"_deposit":{"created_by":18,"id":"8030","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"8030"},"status":"published"},"_oai":{"id":"oai:muroran-it.repo.nii.ac.jp:00008030","sets":["35:147"]},"author_link":["42733","426","36934"],"item_77_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1985-11-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"134","bibliographicPageStart":"125","bibliographicVolumeNumber":"35","bibliographic_titles":[{"bibliographic_title":"室蘭工業大学研究報告. 理工編","bibliographic_titleLang":"ja"},{"bibliographic_title":"Memoirs of the Muroran Institute of Technology. Science and engineering","bibliographic_titleLang":"en"}]}]},"item_77_description_23":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_77_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have developed measuring system for arc duration time of commutation spark, which is fabricated to evaluate a commutation action of D-C machine quantitavely. The superior features of the developed system are as follows 1) It is enables measuring of the duration time of commutation spark all of the commutator segment. 2) Accuracy of the system is within 0.1 μs. with 0.5 ms. commutator period (maximum rotation number). 3) It makes possible the long time automatic measurement. We have measured the duration time of commutation arc to JEC-54 commutation spark number. Findings are: 1) The ratio of frequency distribution has two peaks to the duration time of commutation arc. 2) The maximum point of arc duration time in the ratio of frequency distribution increases according to the commutation spark number. 3) Arc duration time depends on brush materials and revoling speed with the same commutation spark number which is measured with eye. It suggests that evaluation of commutation spark with eye measurement is inaccurate. Hence, quantitave measurement is necessary.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_77_publisher_11":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"室蘭工業大学","subitem_publisher_language":"ja"}]},"item_77_relation_15":{"attribute_name":"論文ID(NAID)","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"40003627619","subitem_relation_type_select":"NAID"}}]},"item_77_rights_19":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"copyright© 1985 室蘭工業大学","subitem_rights_language":"ja"}]},"item_77_source_id_12":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05802415","subitem_source_identifier_type":"PISSN"}]},"item_77_source_id_14":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00238225","subitem_source_identifier_type":"NCID"}]},"item_77_subject_9":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"566","subitem_subject_scheme":"NDC"}]},"item_77_version_type_21":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"鈴木, 好夫","creatorNameLang":"ja"},{"creatorName":"スズキ, ヨシオ","creatorNameLang":"ja-Kana"},{"creatorName":"SUZUKI, Yoshio","creatorNameLang":"en"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"沢井, 孝哉","creatorNameLang":"ja"},{"creatorName":"SAWAI, Takaya","creatorNameLang":"en"},{"creatorName":"サワイ, タカヤ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"松田, 敏彦","creatorNameLang":"ja"},{"creatorName":"MATSUDA, Toshihiko","creatorNameLang":"en"},{"creatorName":"マツダ, トシヒコ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-16"}],"displaytype":"detail","filename":"kiyo35_rikou_pp125-134.pdf","filesize":[{"value":"867.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"kiyo35_rikou_pp125-134.pdf","objectType":"fulltext","url":"https://muroran-it.repo.nii.ac.jp/record/8030/files/kiyo35_rikou_pp125-134.pdf"},"version_id":"153da3ce-5335-4ddd-a4e0-3f24e344d22c"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"整流火花アーク継続時間測定装置とその火花号数検討への応用","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"整流火花アーク継続時間測定装置とその火花号数検討への応用","subitem_title_language":"ja"},{"subitem_title":"Measuring System for Duration Time of Commutation Spark and Application to the Study of Commutation Spark Number","subitem_title_language":"en"}]},"item_type_id":"77","owner":"18","path":["147"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2014-03-04"},"publish_date":"2014-03-04","publish_status":"0","recid":"8030","relation_version_is_last":true,"title":["整流火花アーク継続時間測定装置とその火花号数検討への応用"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2024-01-23T02:54:07.074903+00:00"}