{"created":"2023-06-19T10:29:54.653596+00:00","id":9988,"links":{},"metadata":{"_buckets":{"deposit":"a05f00ff-1d7f-4cd2-82d2-3012adfe9e17"},"_deposit":{"created_by":18,"id":"9988","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"9988"},"status":"published"},"_oai":{"id":"oai:muroran-it.repo.nii.ac.jp:00009988","sets":["216:225","216:273","46"]},"author_link":["56306","56305","54164"],"item_79_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-09-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"1088","bibliographicPageStart":"1083","bibliographicVolumeNumber":"47","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Plasma Science","bibliographic_titleLang":"en"}]}]},"item_79_description_23":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_79_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Positive and negative pulsed discharge plasma is generated above test liquid containing NaCl in Ar atmosphere, and the spatiotemporal variation of pH value in the liquid is visualized by a colorimetric method using bromothymol blue. Furthermore, polarity effects on H 2 O 2 generation are examined by electrochemical calculation and a colorimetric method using titanium sulfate. When the positive pulsed discharge plasma is generated, the pH value of the liquid is decreased by H + generation through the dissociation of H 2 O +, formed by the charge exchange reaction between Ar + and H 2 O, while the pH value of the vicinity of an earthed electrode is increased by OH - generation through the electrolysis of water. When the negative pulsed discharge plasma is generated, the pH value of the liquid is increased by OH - generation and H + reduction, respectively, through the reaction of hydrated electrons with H 2 O and H +, while the pH value in the vicinity of the earthed electrode is decreased by H + generation through the electrolysis of water. The generation of H 2 O 2 is found to be promoted when the positive pulsed discharge plasma is generated, and this increase rate of H 2 O 2 is in approximate agreement with the calculated generation rate of H 2 O 2, which is produced from OH generated by electrolysis.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_79_link_17":{"attribute_name":"出版者版へのリンク","attribute_value_mlt":[{"subitem_link_text":"10.1109/TPS.2018.2866282","subitem_link_url":"https://doi.org/10.1109/TPS.2018.2866282"}]},"item_79_link_5":{"attribute_name":"室蘭工業大学研究者データベースへのリンク","attribute_value_mlt":[{"subitem_link_text":"髙橋 一弘(TAKAHASHI Kazuhiro)","subitem_link_url":"http://rdsoran.muroran-it.ac.jp/html/100000193_ja.html"},{"subitem_link_text":"佐藤 孝紀(SATOH Kohki)","subitem_link_url":"http://rdsoran.muroran-it.ac.jp/html/100000024_ja.html"}]},"item_79_publisher_11":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE","subitem_publisher_language":"en"}]},"item_79_relation_18":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1109/TPS.2018.2866282","subitem_relation_type_select":"DOI"}}]},"item_79_rights_19":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.","subitem_rights_language":"en"}]},"item_79_source_id_12":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00933813","subitem_source_identifier_type":"PISSN"}]},"item_79_source_id_14":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA0066803X","subitem_source_identifier_type":"NCID"}]},"item_79_subject_9":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"436","subitem_subject_scheme":"NDC"}]},"item_79_version_type_21":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"WAKISAKA, Shogo","creatorNameLang":"en"},{"creatorName":"脇坂, 尚吾","creatorNameLang":"ja"},{"creatorName":"ワキサカ, ショウゴ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"TSUDA, Koshi","creatorNameLang":"en"},{"creatorName":"津田, 倖司","creatorNameLang":"ja"},{"creatorName":"ツダ, コウシ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{}],"affiliationNames":[{},{}]}],"creatorNames":[{"creatorName":"TAKAHASHI, Kazuhiro","creatorNameLang":"en"},{"creatorName":"髙橋, 一弘","creatorNameLang":"ja"},{"creatorName":"タカハシ, カズヒロ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{}],"affiliationNames":[{},{}]}],"creatorNames":[{"creatorName":"TAKAHASHI, Kazuhiro","creatorNameLang":"en"},{"creatorName":"髙橋, 一弘","creatorNameLang":"ja"},{"creatorName":"タカハシ, カズヒロ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-02"}],"displaytype":"detail","filename":"IEEETPS_47_2_1083_1088.pdf","filesize":[{"value":"587.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"IEEETPS_47_2_1083_1088","objectType":"fulltext","url":"https://muroran-it.repo.nii.ac.jp/record/9988/files/IEEETPS_47_2_1083_1088.pdf"},"version_id":"26b210ef-5b62-4a9f-b771-8b812456539b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Colorimetric method","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"pH measurement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"plasma applications","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"pulsed discharge plasma","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Mechanism of pH variation and H2O2 generation in water exposed to pulsed discharge plasma","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Mechanism of pH variation and H2O2 generation in water exposed to pulsed discharge plasma","subitem_title_language":"en"}]},"item_type_id":"79","owner":"18","path":["46","273","225"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2019-07-02"},"publish_date":"2019-07-02","publish_status":"0","recid":"9988","relation_version_is_last":true,"title":["Mechanism of pH variation and H2O2 generation in water exposed to pulsed discharge plasma"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2024-02-14T03:14:08.854734+00:00"}